| GFM 1050 | GFM 1050 |
Automatic hood opening via electromechanical spindle
Flap with inspection glass as additional equipment for easy observation of the glass.
GFM 420 - GFM 1050
The GFM series was developed to meet the special requirements of production. Depending on the application, different tabletop and tub systems are available for delivery. A movable table system on castors is supplied as a standard for fusing applications. Various tables and tubs with different heights and numerous additional equipments are available as system add-ons. Especially economical is the alternating table system, in which one table is loaded while the other one is in the furnace.
- Tmax 950 °C
- Infrared heated in hood which is atteched to stand
- Delivered with one table
- Freely movable table on wheels
- Infrared heating elements for short heat-up times and energy-saving operation
- Lid heating elements for direct radiation on the surface of the glass
- Low-noise heating operation with solid-state relays
- NiCr-Ni thermocouple inside the furnace for precise temperature measurement
- Insulation with special ceramic fibres for short heat-up and cool-down times
- Housing made from high-quality stainless steel and lid with ventilation ports (avoidance of rust formation during drying of plaster moulds)
- Attractive design and solid construction
- Gas dampers facilitate opening and closing of hood
- Adjustable locks for easy handling
- Large metal handle for opening and closing furnace
- Supply air and glass inspection ports with insulated doors, viewing window as an additional equipment
Additional features for fusing furnaces GF and GFM
- Automatic lid opening for faster cooling, programmable via the extra controller function, for models GF 380 and/or GFM 380 up
| Model | Tmax | Inner dimensions in mm | Floor space | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in m² | W | D | H | power/kW | connection* | in kg | |
| GFM 420 | 950 | 1650 | 850 | 380 | 1,40 | 2400 | 1480 | 1400 | 18 | 3-phase | 410 |
| GFM 520 | 950 | 1200 | 1150 | 380 | 1,38 | 1950 | 1780 | 1400 | 15 | 3-phase | 430 |
| GFM 600 | 950 | 2000 | 1000 | 380 | 2,00 | 2750 | 1630 | 1400 | 22 | 3-phase | 610 |
| GFM 920 | 950 | 2100 | 1150 | 380 | 2,42 | 2850 | 1780 | 1400 | 26 | 3-phase | 740 |
| GFM 1050 | 950 | 2300 | 1200 | 380 | 2,76 | 3050 | 1830 | 1400 | 32 | 3-phase | 860 |
| *Please see page 25 for more information about supply voltage | |||||||||||